Showing all 5 results

  • Skalar – Automated Wet Chemistry Analyzer – San Series

    The San Series of Automated Wet Chemistry Analyzers also known as Continuous Flow Analyzers have been designed as modular systems to meet the needs of laboratories that process a few samples or large volumes of samples. Based on the Continuous Flo...

    The San Series of Automated Wet Chemistry Analyzers also known as Continuous Flow Analyzers have been designed as modular systems to meet the needs of laboratories that process a few samples or large volumes of samples. Based on the Continuous Flow Analysis (CFA) or also called Segmented Flow Analysis (SFA) technique, up to 16 analytical measurements (depending on the model) can be made on a single sample simultaneously. With the addition of rinsing valves and software the San Series of analyzers can automate; start-up, shut-down, dilutions, re-runs, clean-up, and raw data storage

  • Skalar – BluVision Discrete Analyzer

    The BluVisionTM is specially designed for environmental labs that have a wide variety of sample types and matrices for analysis. The Skalar discrete analyzer automates the sample & reagent pipetting into the cuvettes, mixing, heating and meas...

    The BluVisionTM is specially designed for environmental labs that have a wide variety of sample types and matrices for analysis. The Skalar discrete analyzer automates the sample & reagent pipetting into the cuvettes, mixing, heating and measuring of the reaction product.

  • Skalar – Robotic Analyzer – SP2000

    The SP2000 analyzers automate all manual handling steps in the procedure of an application such as sample dilution, capping / de-capping, liquid handling, mixing, addition of reagents etc. Skalar has automated the following appl...

    The SP2000 analyzers automate all manual handling steps in the procedure of an application such as sample dilution, capping / de-capping, liquid handling, mixing, addition of reagents etc. Skalar has automated the following applications:

    • Biochemical Oxygen Demand (BOD)
    • Chemical Oxygen Demand (COD) according to ISO 6060
    • Test kit applications including ST-COD according to ISO 15705, pH, Conductivity (EC), Alkalinity, Acidity, Hardness, Carbonate / Bicarbonate and other titrations, Turbidity and Color, Ion Selective Electrode (ISE) measurements
    • Particle size distribution analysis in soil
    • Bitterness and other parameters in beer/wort
    • Sample preparation techniques (filtration, distribution, pipetting etc.)
  • Skalar – TOC & TN Analyzer for Liquid Sample – Formacs Series

    The Formacs SERIES Total Organic Carbon (TOC) and Total Nitrogen (TN) analyzers have been designed to measure TOC and TN separately or simultaneously in liquid samples.

    The flexible design ensures optimal performance and is operational with...

    The Formacs SERIES Total Organic Carbon (TOC) and Total Nitrogen (TN) analyzers have been designed to measure TOC and TN separately or simultaneously in liquid samples.

    The flexible design ensures optimal performance and is operational within minutes, providing accurate analyses for Total Carbon (TC), Total Inorganic Carbon (TIC), TOC, Non-Purgeable Organic Carbon (NPOC), and TN. As an additional option, the concentration of Nitrate and Nitrite (NN) can be measured which results in a true alternative to the Total Kjeldahl Nitrogen (TKN) method (TKN = TN – NN). This eliminates the need for hazardous reagents, which are required for the conventional TKN analysis. In this way, valuable operator time is saved and better precision is achieved.

    The user-friendly analyzers allow quick and easy access to all components and include a versatile software package for complete instrument control, data acquisition, calculations, and report generation.

  • Skalar – TOC & TN Analyzer for Solid & Liquid Sample – Primacs Series

    The PrimacsSERIES provides fast, reliable, accurate, and low-level analysis of Total Nitrogen / Protein, Total Carbon, Total Organic Carbon, Total Elemental Carbon, and Total Inorganic Carbon all in one unit.

    The PrimacsSERIES provides fast, reliable, accurate, and low-level analysis of Total Nitrogen / Protein, Total Carbon, Total Organic Carbon, Total Elemental Carbon, and Total Inorganic Carbon all in one unit.

    The measurement of TC, TOC, TEC, and TIC is based on high-temperature catalytic combustion with Non-Dispersive Infrared detection (NDIR). The temperature settings are variable and a special temperature ramping program allows the analysis of TEC, according to DIN 19539. The TN/Protein analysis is based upon DUMAS methodology and detection with Thermal Conductivity (TCD). TIC can also be determined separately using automatic acidification and purging. All systems come with a practical and flexible software package, with pre-installed method files, user-definable sample table set up, integrated QC features, etc.

    The analyzer contains a large integrated 100 position autosampler with a unique vertical sample introduction system. The sample ashes remain in the crucible after the analysis and are taken out to the instrument with the removal of the crucible. This avoids sample ash build-up in the combustion zone and therefore reduces maintenance.